Routine Maintenance
Logging In
Serial Connection:
1. Launch the terminal or terminal emulator.
2. Press RETURN four times within 1 second, and then follow the prompts.
3. Select a Terminal Type.
4. Select 1 - MAINTENANCE.
5. Enter your username and password.
Secure Telnet Connection:
1. Launch the secure Telnet client.
2. Enter the hostname or IP address of the controller, and port 2000—for
example, to open a connection from a Mitel Telnet client, enter: op
192.168.2.25 2000
3. Log in to SSL/TLS with login name ‘installer’ and default password
‘1000.’
4. Select a Terminal Type.
5. Select 1 - MAINTENANCE.
6. Log in to the application with your username and password.
SX-200 ICP Web Interface Connection:
1. Launch the web browser.
2. Enter https://<controller IP or hostname>:443
For example, https://10.33.63.118:443
3. Log in to the SX-200 ICP Web Interface with login name ‘installer’ and
default password ‘1000.’
4. Select a Terminal Type.
5. Select 1 - MAINTENANCE.
6. Log in to the application with your username and password.
Logging Out
1. Press QUIT (softkey 6).
2. Press key 6 (or wait for logout timer to time out).